Toilet and Shower

Electrical Certificate

  • Australian Licenced Electrican Test Certificate – Electrical Safety Regulation 2013

Power and Lighting

  • Australian Standards compliant light and power cable installed
  • Australian Standards compliant light switches and power points installed
  • Australian Standards compliant IP66 rated Electrical Distribution Board fitted
  • EDB is fitted with 1 x 2 pole 10amp circuit breaker
  • Australian Standards compliant fixtures and fittings supplied fitted including 3 pin GPO, exhaust fan, internal ceiling light and light switch included
  • Compliance to AS3000 and AS3001

Bathroom

  • Shower with rain maker shower head, Shower rail, Vanity with sink and flick mixer, overhead cupboard with mirror, toilet with soft close lid and exhaust fan
  • Plumbing complete inside the building and ready for connection outside

WELS Compliance

  • All fixtures & fittings are WELS WATERMARK AS/NZS 6400:2016 compliant
  • Toilet: WELS 4 Star, 4.5L full/3.1L half/3.4L average flush, Registration number L07047
  • Hand basin tapware: WELS 5 Star, 6.0L/min, Registration number T38665
  • Shower head: WELS 3 Star, 9.0L/min, Registration number S15160
  • Hand shower: WELS 3 Star, 9.0L/min, Registration number S15318

Council Compliant

  • WELS compliant fixtures and fittings
  • Electrical Test certificate to AS3000 Compliance
  • Engineer’s Structural Certification available on request – additional charges apply. This includes:
    • Detailed plans for council submission
    • Engineer footing design available, engineer certification by others

Equipment Installed

  • 4 lifting lugs and forklift pockets for transport
  • Easy clean floor, walls and ceiling
  • Vented, key lockable door in steel frame
  • Polycarbonate shower screen
  • Shower curtain
  • Toilet roll holders
  • Toilet brush and wall mounted holder
  • Soap holder

Manufacture and Fittings

  • Strong shipping container style structure with insulated sides and roof

Roof

  • Centre section: Top Galvanized Prepainted 3mm Steel Cover + 50mm EPS insulation sheeted both side with .4mm prepainted steel sheet.
  • Main roof: 50mm EPS insulation sheeted both side with .4mm prepainted steel sheet
  • Roof is sealed and protected steel sheet

Window and Door

  • Double glazed window and Solid lockable door

Floor

  • BULU water and anti insect proof floor; finished with a thick vinyl

Dimensions (open)

  • L: 2250mm x W: 2100mm x H: 2370mm x Weight 700Kg

Installation

  • Place on level ground and connect to services
  • 4 adjustable feet to level the building

Footing options

  • Concrete slab or pads
  • Compacted ground
  • Concrete or Steel stumps
  • Note: Finished height of surface must be level. Consulting a qualified person is recommended.

Final Connections

  • Final connection of service to the building is by the customer
  • Form 7 is to be provided by the customer’s plumber connecting the building to mains water and sewerage

Price $8,400